Hi guys, I need a little help if its possible. Common issue in Jaguar's X250 cars. After disconnection of battery from the car (Jaguar XF 3.0SC 2013), central lock is inoperative. Alarm is engaged but locks still open. Always the best way, was to configure BCM as existing module or as a new module using SDD. But this time, the BCM in the car was previously taken from another car (vin mismatch). When I try to start the procedure configure as existing module, system want to start the operation with message that the newest softer is already installed. When I try function configure as a new module procedure fail with the message "Failed to write target security identifier". I also tried to use engineer access using seed to vin bypass, also without success. I checked that cff file has correct vin number, but informations about the part - BCM has another from the car. What else can I do? How to flash this module when it has incorrect vin number? Thanks for reply
↧